Powered by GoogleTranslate

Inspection Detail

Inspection: 304564321 - Appalachian Sign, Llc

Inspection Information - Office: Nc Department Of Labor - Charlotte

 

Inspection Nr: 304564321
Report ID: 0453730
Date Opened: 05/23/2001

Site Address:
Appalachian Sign, Llc
Carolina Shopping Center, 2600 Block
Lenoir, NC 28645

Mailing Address:
Po Box 347, Lenoir, NC 28645

Union Status: NonUnion

SIC:3646

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/23/2001

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 10/29/2001


Related Activity
Type Activity Nr Safety Health
Accident 102092491
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $2,100 $0 $0 $0 $0 $2,100
Current Penalty $1,208 $0 $0 $0 $0 $1,208
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100304 F05 IVA 07/02/2001 07/08/2001 $0 $1,050 $0 I - Informal Settlement  
2. 01002A Serious 19100304 F04 07/02/2001 07/08/2001 $683 $0 $0 I - Informal Settlement  
3. 01002B Serious 19100304 A02 07/02/2001 07/08/2001 $0 $0 $0 -  
4. 01003 Serious 19100333 B02 07/02/2001 07/20/2001 $525 $1,050 $0 I - Informal Settlement  
5. 01004 Serious 19100334 A02 I 07/02/2001 07/08/2001 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 202074704
Event: 05/23/2001
Electric Shock - Ground Fault in Electric Sign

An employee was trying to locate a fault that was causing a loss of power to some lights in an electric sign. He contacted the frame of the sign and was electrocuted. Energized parts of one of the three ballasts for the sign were touching the metal frame of the sign, energizing it to 700 volts. In addition, the extension cord set he had used to connect the generator from his maintenance truck to the sign was not grounded. The employee died at the scene.

Keywords: E GI II, ELEC PROTECT EQUIP, ELECTRICAL, ELECTRIC SIGN, CORD SET, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304564321 Fatality Electric Shock Specified mechanics and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.