Inspection Detail
Inspection: 304465842 - Wyeth Pharmaceuticals
Inspection Information - Office: Albany Area Office
Site Address:
Wyeth Pharmaceuticals
64 Maple Street
Rouses Point, NY 12979
Mailing Address:
, , 00000
Union Status: Union
SIC:8731
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/21/2002
Emphasis:
Case Closed: 05/22/2002
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 200744449 | Yes |
Investigation Summary
Employee #1 was involved in draining a process tank. When Employee #1 was attempting to attach a drain hose to the process tank, he first had to remove a quick disconnect cap from the bottom of the tank. When Employee #1 removed the cap he was sprayed with hot water and steam. The drain valve apparently had been left in the open position. Employee #1 sustained second degree burns over 40 percent of his body. Employee #1 was hospitalized.
Keywords: BURN, HEAT, STEAM, HOT WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 304465842 | Hospitalized injury | Burn/Scald(Heat) | Mixing and blending machine operators |