Powered by GoogleTranslate

Inspection Detail

Inspection: 304411895 - El Paso Field Services

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 304411895
Report ID: 0854910
Date Opened: 09/17/2001

Site Address:
El Paso Field Services
Rhodes Moon Central Tank Battery, 7 Mi North
Duchesne, UT 84021

Mailing Address:
1176 E 1500 S Po Box 970, Vernal, UT 84078

Union Status: NonUnion

SIC:4213

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 01/10/2002

Planning Guide: Health-Manufacturing

Emphasis: S:Services

Case Closed: 12/31/2001


Related Activity
Type Activity Nr Safety Health
Accident 362654261
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 1 5
Current Violations
Initial Penalty $3,465 $0 $0 $250 $0 $3,715
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 10005 D03 02/28/2002 04/16/2002 $900 $900 $0 04/01/2002 J - ALJ Decision Citation has been deleted.
2. 01001B Serious 19100106 F03 IVC 02/28/2002 03/19/2002 $0 $0 $0 04/01/2002 J - ALJ Decision Citation has been deleted.
3. 01002A Serious 19100132 D02 02/28/2002 04/16/2002 $900 $900 $0 04/01/2002 J - ALJ Decision Citation has been deleted.
4. 01002B Serious 19100132 F01 02/28/2002 04/16/2002 $0 $0 $0 04/01/2002 J - ALJ Decision Citation has been deleted.
5. 01003 Serious 19100134 D01 III 02/28/2002 04/16/2002 $900 $900 $0 04/01/2002 J - ALJ Decision Citation has been deleted.
6. 01004A Serious 19101200 B04 II 02/28/2002 03/06/2002 $765 $765 $0 04/01/2002 J - ALJ Decision Citation has been deleted.
7. 01004B Serious 19101200 E01 02/28/2002 03/06/2002 $0 $0 $0 04/01/2002 J - ALJ Decision Citation has been deleted.
8. 02001 Other 10008 C01 02/28/2002 04/16/2002 $250 $250 $0 04/01/2002 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 171061443
Event: 09/17/2001
Employee Asphyxiated Inhaling Hydrocarbon Fumes

Employee #1, a transport driver, was top-loading his tanker with petroleum crude oil using gravity feed lines. Employee #1 was at a central tank battery or blending plant, where the black-wax crude oil is heated and then blended with a natural gasoline condensate product or ingredient requested by the customer. Employee #1 was found face down, lying in the top well near the open hatch of the first tanker of the tandem tanker trailers. Employee #1 was asphyxiated.

Keywords: ASPHYXIATED, CRUDE OIL, GASOLINE, TRUCK DRIVER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304411895 Fatality Asphyxia Truck drivers, heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close