Powered by GoogleTranslate

Inspection Detail

Inspection: 304410806 - Flying J

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 304410806
Report ID: 0854910
Date Opened: 08/10/2001

Site Address:
Flying J
333 W Center St
North Salt Lake, UT 84054

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2911

NAICS: 324110/Petroleum Refineries


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/14/2001

Planning Guide: Safety-Manufacturing

Emphasis: S:Manufacturing

Case Closed: 11/01/2003


Related Activity
Type Activity Nr Safety Health
Accident 362654105
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 3 7
Current Violations 3 3 6
Initial Penalty $14,000 $0 $0 $2,000 $0 $16,000
Current Penalty $5,250 $0 $0 $750 $0 $6,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100023 A02 02/01/2002 02/15/2002 $1,750 $3,500 $0 03/13/2002 F - Formal Settlement  
2. 01002A Serious 19100119 D01 02/01/2002 03/21/2002 $1,750 $3,500 $0 03/13/2002 F - Formal Settlement  
3. 01002B Serious 19100119 E03 02/01/2002 03/21/2002 $0 $0 $0 03/13/2002 F - Formal Settlement  
4. 01002C Serious 19100119 F01 02/01/2002 03/21/2002 $0 $0 $0 03/13/2002 F - Formal Settlement  
5. 01002D Serious 19100119 G01 I 02/01/2002 03/21/2002 $0 $0 $0 03/13/2002 F - Formal Settlement  
6. 01003A Serious 19100146 D02 02/01/2002 03/21/2002 $1,750 $3,500 $0 03/13/2002 F - Formal Settlement  
7. 01003B Serious 19100146 E01 02/01/2002 03/21/2002 $0 $0 $0 03/13/2002 F - Formal Settlement  
8. 01003C Serious 19100146 G01 02/01/2002 03/21/2002 $0 $0 $0 03/13/2002 F - Formal Settlement  
9. 01004A Serious 19100147 C02 II 02/01/2002 03/21/2002 $3,500 $3,500 $0 03/13/2002 F - Formal Settlement Citation has been deleted.
10. 01004B Serious 19100147 C04 II 02/01/2002 03/21/2002 $0 $0 $0 03/13/2002 F - Formal Settlement Citation has been deleted.
11. 02001 Other 10005 C02 02/01/2002 02/07/2002 $0 $500 $0 03/13/2002 F - Formal Settlement  
12. 02002 Other 19100132 A 02/01/2002 02/07/2002 $375 $750 $0 03/13/2002 F - Formal Settlement  
13. 02003 Other 19100305 G02 III 02/01/2002 02/07/2002 $375 $750 $0 03/13/2002 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201560505
Event: 08/10/2001
Employee hospitalized when scalded during cleaning operation

On August 10, 2001, an employee was cleaning a flash drum during a planned maintenance shutdown of a reformer unit. The employee was on a catwalk elevated 20 feet above the ground where an access door to the flash drum was located. He was using a 2-inch water hose with a steel nozzle to clean the flash drum. The employee was scalded during the cleaning operation and was hospitalized. He was not adequately trained to recognize the hazards of his job.

Keywords: BURN, CLEANING, DRUM, WATER HOSE, UNTRAINED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304410806 Hospitalized injury Burn/Scald(Heat) Miscellaneous plant and system operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close