Powered by GoogleTranslate

Inspection Detail

Inspection: 304318587 - Hunter Environmental Services, Inc.

Inspection Information - Office: Jackson Area Office

 

Inspection Nr: 304318587
Report ID: 0419400
Date Opened: 04/03/2003

Site Address:
Hunter Environmental Services, Inc.
Waterway Drive
Amory, MS 38821

Mailing Address:
245 Fannin Landing Circle, Brandon, MS 39047

Union Status: NonUnion

SIC:1623

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 05/15/2003

Emphasis: L:Workzone, N:Trench, S:Construction Fatalities

Case Closed: 07/05/2005


Related Activity
Type Activity Nr Safety Health
Accident 101363224
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 6
Current Violations 6 6
Initial Penalty $22,150 $0 $0 $0 $0 $22,150
Current Penalty $12,000 $0 $0 $0 $0 $12,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 06/10/2003 06/24/2003 $500 $1,500 $0 I - Informal Settlement  
2. 01002 Serious 19260651 C02 06/10/2003 06/16/2003 $2,500 $4,900 $0 I - Informal Settlement  
3. 01003 Serious 19260651 D 06/10/2003 06/16/2003 $500 $1,050 $0 I - Informal Settlement  
4. 01004 Serious 19260651 J02 06/10/2003 06/16/2003 $3,000 $4,900 $0 I - Informal Settlement  
5. 01005 Serious 19260651 K01 06/10/2003 06/16/2003 $2,500 $4,900 $0 I - Informal Settlement  
6. 01006 Serious 19260652 A01 06/10/2003 06/16/2003 $3,000 $4,900 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 201361961
Event: 04/03/2003
Employee killed when trench wall caves in

At approximately 9:30 a.m. on April 3, 2003, Employee #1 was making a joint connection at the south end of an excavation. A 6-in. sewer line was being installed along the west side of an industrial park access road. The depth of the pipe ranged from 5.25 ft to 8.65 ft below grade. The excavation was opened to a width of 5 ft and extended 90 ft in a north-south direction along the west side of the road. The spoils were placed directly on the edge of the excavation so as to not block the road. The walls were not sloped and no shoring was being used. The east wall collapsed and buried Employee #1. The other employees called emergency medical technicians and started to dig Employee #1 out. When the emergency medical technicians arrived, Employee #1 was extricated from the excavation and pronounced dead at the scene.

Keywords: EXCAVATION, ASPHYXIATED, WALL, COLLAPSE, CONSTRUCTION, TRENCH, SHORING, CAVE-IN

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304318587 Fatality Asphyxia Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.