Inspection Detail
Inspection: 304247281 - Mar-B Plumbing Corporation
Inspection Information - Office: Fort Lauderdale Area Office
Site Address:
Mar-B Plumbing Corporation
2200 Nw 78th Ave
Pembroke Pines, FL 33024
Mailing Address:
104 Crandon Blvd. Suite 402, Key Biscayne, FL 33149
Union Status: NonUnion
SIC:1711
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/04/2002
Emphasis: L:Flcare, S:Construction
Case Closed: 03/12/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100674415 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 2 | 1 | 3 | |||
| Initial Penalty | $1,050 | $0 | $0 | $0 | $0 | $1,050 |
| Current Penalty | $788 | $0 | $0 | $0 | $0 | $788 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19260416 E01 | 01/04/2002 | 01/10/2002 | $394 | $525 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19260403 B01 | 01/04/2002 | 01/24/2002 | $0 | $0 | $0 | I - Informal Settlement | ||
| 3. | 01001C | Serious | 19260403 B01 VI | 01/04/2002 | 01/10/2002 | $0 | $0 | $0 | I - Informal Settlement | ||
| 4. | 01001D | Serious | 19260403 B02 | 01/04/2002 | 01/16/2002 | $0 | $0 | $0 | I - Informal Settlement | ||
| 5. | 01002 | Serious | 19260405 G01 I | 01/04/2002 | 01/10/2002 | $394 | $525 | $0 | I - Informal Settlement | ||
| 6. | 02001 | Other | 19260403 G | 01/04/2002 | 01/30/2002 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 2:00 p.m. on August 14, 2001, Employee #1, was operating an electric concrete coring drill on the second floor of a condominium under construction. Coworkers found him lying in a puddle of water, and he was pronounced dead at the scene. He was electrocuted due to a short circuit in the drill.
Keywords: PORTABLE POWER TOOL, ELECTROCUTED, CONSTRUCTION, ELECTRICAL FAULT, ELECTRIC DRILL, MECH MALFUNCTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 304247281 | Fatality | Electric Shock | Occupation not reported |
Translate