Powered by GoogleTranslate

Inspection Detail

Inspection: 304038193 - Mueller Copper Tube Products

Inspection Information - Office: Little Rock Area Office

 

Inspection Nr: 304038193
Report ID: 0627100
Date Opened: 12/22/2000

Site Address:
Mueller Copper Tube Products
1525 North Falls Blvd
Wynne, AR 72396

Mailing Address:
P. O. Box 309, Wynne, AR 72396

Union Status: Union

SIC:3351

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 01/04/2001

Emphasis:

Case Closed: 05/30/2001


Related Activity
Type Activity Nr Safety Health
Accident 100260983
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1 2
Initial Penalty $4,125 $0 $0 $0 $0 $4,125
Current Penalty $1,500 $0 $0 $0 $0 $1,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 5A0001 05/02/2001 05/08/2001 $1,500 $2,625 $0 I - Informal Settlement  
2. 01001B Serious 19100133 A01 05/02/2001 05/08/2001 $0 $0 $0 I - Informal Settlement  
3. 01002 Other 19101200 H03 II 05/02/2001 05/29/2001 $0 $1,500 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200261444
Event: 12/22/2000
Employees Burned by Erupting Molten Metal

At approximately 11:34 a.m. on December 22, 2000, Employee #1, #2 and #3 had initiated a metal casting process in the casting pit when molten metal erupted from the pit. The process was a semi-continuous direct chill casting process. An electric arc casting furnace was used to melt copper raw material. The copper was poured from the furnace into a launder (pouring tundish) and then into three copper molds which were 11 in. in diameter and 19.44 in. long. The final product was copper logs that were approximately 22.6 in. in length and 11 in. in diameter. The explosion involving the casting of the molten copper process occurred in the East Casting Machine in Mold Number 6. The blast forced the pivoted point of the launder upward and discharged most of the copper from the mold. Prior to the explosion, the three employees were having problems maintaining the proper flow rate into Mold Number 6 because of the spout became clogged with debris. One of the employees used a lance rod to clear the spout. While attempting to clear the spout and regulate the molten copper flow into the mold, the explosion occurred and sprayed molten metal upon the workers. They all received severe burns and were hospitalized. In the hospital, they were treated for multiple burns located on various body regions. From the inspection of the Casting Machine, the copper shell in the Mold Number 6 after the explosion had become lodged within the mold and separated from the mold cup. As for the log, it did not travel downwards with the mold cup but left a space between the log and the mold cup. The creation of a space between these two articles is likely due to water or condensation being introduced into the mold cup. As the molten copper or formed copper log contacted the moisture in the space, the heat caused the liquid to vaporize causing a rapid expansion of super-heated steam. This steam forced its way through a weak spot in the shell bottom and propelled the molten metal from the mold.

Keywords: BURN, CASTING, MOLTEN METAL, PIT, METAL INGOT, FORMING MACHINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 304038193 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 304038193 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 304038193 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close