Inspection Detail
Inspection: 304009301 - P H Glatfelter Company
Inspection Information - Office: Appleton Area Office
Site Address:
P H Glatfelter Company
Mill - 225 W. Wisconsin Ave.
Neenah, WI 54956
Mailing Address:
Bergstrom Road, Neenah, WI 54956
Union Status: Union
SIC:2621
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/22/2001
Emphasis: S:Amputations
Case Closed: 08/22/2001
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Complaint | 200661551 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 2 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
| Current Penalty | $2,100 | $0 | $0 | $0 | $0 | $2,100 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100120 Q03 III | 08/07/2001 | 08/17/2001 | $1,050 | $1,500 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100120 Q03 IX | 08/07/2001 | 08/07/2001 | $0 | $0 | $0 | - | ||
| 3. | 01002 | Serious | 19100261 A03 VI | 08/07/2001 | 08/10/2001 | $1,050 | $1,500 | $0 | I - Informal Settlement |
Investigation Summary
A steam release in a building housing two caustic soda tanks migrated into an area housing two paper machines at a paper mill. It is believed that the steam dissolved some crystallized caustic underneath a catwalk, causing a caustic mist. This mist was drawn to the paper machines because of the large amount of air exhausted by the hoods. The area of the paper machines was evacuated due to respiratory irritation experienced by employees, and the visible mist in the room. Employee's #1, #2, and #3 who were in the area of the paper machines, later went to the emergency room, were treated and released.
Keywords: RESPIRATORY, VAPOR, CAUSTIC, STEAM, TANK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 304009301 | Non Hospitalized injury | Other | Occupation not reported | ||
| 2 | 304009301 | Non Hospitalized injury | Other | Occupation not reported | ||
| 3 | 304009301 | Non Hospitalized injury | Other | Occupation not reported |