Powered by GoogleTranslate

Inspection Detail

Inspection: 303982151 - C & C Construction

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 303982151
Report ID: 0352440
Date Opened: 08/27/2000

Site Address:
C & C Construction
10409 Crestmoor Drive
Silver Spring, MD 20901

Mailing Address:
17435 General Lee Drive, Sharpsburg, MD 21782

Union Status: NonUnion

SIC:1751

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/13/2000

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/13/2000


Related Activity
Type Activity Nr Safety Health
Accident 100967272

Investigation Summary

Investigation Nr: 200963692
Event: 08/27/2000
Electric Shock - Contact with Overhead Line thru Load Line

A bundle of trusses was lying below a 13.8-kilovolt (phase-to-phase) overhead power line that was 10.7 meters above the ground. An employee was going to use a 1988 Grove crane (Model No. TMS 528B, Serial No. 71550) to lift the trusses. The boom had been positioned about 24.4 meters above the ground at an angle of approximately 60 degrees. The employee had attached a synthetic web sling to the hook and was running the sling through the trusses to the hook. He pulled on the load line as he was attaching the sling, and the load line contacted the power line. The employee was electrocuted.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, CONSTRUCTION, E C, LOAD LINE, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303982151 Fatality Electric Shock Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.