Inspection Detail
Inspection: 303931448 - Pike Electric, Inc
Inspection Information - Office: Atlanta West Area Office
Site Address:
Pike Electric, Inc
Bullsboro Dr.
Newnan, GA 30263
Mailing Address:
P. O. Box 868, Mount Airy, NC 27030
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/01/2001
Planning Guide: Safety-Construction
Emphasis: S:Construction Fatalities
Case Closed: 04/03/2002
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100201094 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | ||||||
Initial Penalty | $14,000 | $0 | $0 | $0 | $0 | $14,000 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 07/16/2001 | 08/30/2001 | $0 | $7,000 | $0 | 08/03/2001 | J - ALJ Decision | Citation has been deleted. |
2. | 01002 | Serious | 19260021 B02 | 07/16/2001 | 08/30/2001 | $0 | $7,000 | $0 | 08/03/2001 | J - ALJ Decision | Citation has been deleted. |
Investigation Summary
Two power line workers were in an aerial lift, installing an aerial marker on an overhead power line. They had not extended the outriggers on the aerial lift truck. Two ground workers were approximately 2.4 meters from the back of the truck, rolling up grounds. The power line workers elevated the bucket. When the aerial lift bucket reached a height of approximately 19.8 meters, the ground workers noticed that the passenger-side tires were raised above the ground. The aerial lift overturned, crushing both power line workers to death.
Keywords: OUTRIGGER, POWER LINE WORKER, CRUSHED, ELEC UTILITY WORK, AERIAL LIFT, OVERTURN
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 303931448 | Fatality | Other | Occupation not reported | ||
2 | 303931448 | Fatality | Other | Electrical power installers and repairers |