Inspection Detail
Inspection: 303910913 - Shaffer Lumber Company
Inspection Information - Office: Dallas
Site Address:
Shaffer Lumber Company
10727 Hwy. 79 South
Henderson, TX 75652
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:2411
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/15/2001
Emphasis: L:Millwork
Close Case:08/14/2007
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100781798 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 8 | 8 | ||||
Current Violations | 8 | 8 | ||||
Initial Penalty | $14,700 | $0 | $0 | $0 | $0 | $14,700 |
Current Penalty | $14,700 | $0 | $0 | $0 | $0 | $14,700 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100023 A08 | 12/11/2001 | 12/14/2001 | $1,050 | $1,050 | $0 | - | ||
2. | 01002 | Serious | 19100147 C01 | 12/11/2001 | 12/14/2001 | $2,100 | $2,100 | $0 | - | ||
3. | 01003 | Serious | 19100178 L | 12/11/2001 | 12/14/2001 | $1,050 | $1,050 | $0 | - | ||
4. | 01004 | Serious | 19100213 B03 | 12/11/2001 | 12/14/2001 | $2,100 | $2,100 | $0 | - | ||
5. | 01005 | Serious | 19100303 G02 I | 12/11/2001 | 12/14/2001 | $2,100 | $2,100 | $0 | - | ||
6. | 01006 | Serious | 19100303 G01 I | 12/11/2001 | 12/14/2001 | $2,100 | $2,100 | $0 | - | ||
7. | 01007 | Serious | 19100305 E01 | 12/11/2001 | 12/14/2001 | $2,100 | $2,100 | $0 | - | ||
8. | 01008 | Serious | 19100335 B01 | 12/11/2001 | 12/14/2001 | $2,100 | $2,100 | $0 | - |
Investigation Summary
A plant manager and another employee were greasing a pulley cylinder on the scrap removal belt of a multiblade cutter. The manager was holding the grease line onto the Zerk fitting while the other employee pumped the grease gun to deliver grease to the fitting. The distance between the adjacent belt and a nearby 480-volt junction box for the conductors feeding the cutter was 400 millimeters. The junction box apparently was uncovered. The right arm of the employee pumping the grease contacted conductors in the junction box, and he was electrocuted. (He was pronounced dead at the hospital.) The manager received an electric shock, but did not seek treatment after the accident. (The manager was not listed on an injury line on the original form.)
Keywords:e gi v, electrical, electrocuted, unguarded live parts, electric shock, electrical box
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 303910913 | Fatality | Electric Shock | Occupation not reported |