Inspection Detail
Inspection: 303909741 - East Texas Hydraulics
Inspection Information - Office: Dallas Area Office
Site Address:
East Texas Hydraulics
6293 Reynolds
Tyler, TX 75701
Mailing Address:
P.O. Box 120007, Tyler, TX 75712
Union Status: NonUnion
SIC:7699
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/16/2001
Emphasis:
Case Closed: 07/02/2001
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100781715 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100067 C02 V | 05/24/2001 | 06/06/2001 | $0 | $1,500 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
Employee #1 was in a bucket on the boom of an articulating arm bucket truck. He was actuating the boom to make sure all air pockets were out of the recently repaired hydraulic system. The bucket apparently fell to the ground with the rapid movement, causing Employee #1's head to strike the control panel and throwing him out of the bucket onto the pavement. Employee #1's head injuries proved fatal.
Keywords: EJECTED, HEAD, MECHANIC, HYDRAULIC LINE, AERIAL LIFT, CONTUSION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 303909741 | Fatality | Bruise/Contus/Abras | Occupation not reported |