Inspection Detail
Inspection: 303852537 - Millennium Contracting & Remodeling, Inc.
Inspection Information - Office: Baltimore Area Office
Site Address:
Millennium Contracting & Remodeling, Inc.
Bldg 32, Riverview Estates
Indian Head, MD 20640
Mailing Address:
2062 Hyde Court, Waldorf, MD 20601
Union Status: NonUnion
SIC:1761
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/20/2000
Emphasis:
Case Closed: 09/10/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 102040235 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $2,000 | $0 | $0 | $0 | $0 | $2,000 |
| Current Penalty | $2,000 | $0 | $0 | $0 | $0 | $2,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260451 F06 | 10/25/2000 | 10/30/2000 | $2,000 | $2,000 | $0 | 11/17/2000 | F - Formal Settlement |
Investigation Summary
An employee was dismantling an aluminum pump-jack scaffold. A 9.1-meter-long pole for the scaffold contacted a 7500-volt overhead power line, electrocuting the employee.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, PUMP JACK SCAFFOLD, METAL POLE, E C, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 303852537 | Fatality | Electric Shock | Supervisors; carpenters and related workers |
Translate