Powered by GoogleTranslate

Inspection Detail

Inspection: 303852313 - Perdue Farms, Inc.

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 303852313
Report ID: 0352410
Date Opened: 08/02/2000

Site Address:
Perdue Farms, Inc.
7036 Zion Church Road
Salisbury, MD 21804

Mailing Address:
7036 Zion Church Road, Salisbury, MD 21802

Union Status: NonUnion

SIC:2079

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/08/2000

Emphasis:

Case Closed: 11/06/2000


Related Activity
Type Activity Nr Safety Health
Accident 100967082
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 2 1 3
Initial Penalty $8,500 $0 $0 $0 $0 $8,500
Current Penalty $2,000 $0 $0 $0 $0 $2,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C04 I 09/26/2000 10/29/2000 $1,000 $3,500 $0 I - Informal Settlement  
2. 01002 Serious 19100147 C06 I 09/26/2000 10/29/2000 $1,000 $2,500 $0 I - Informal Settlement  
3. 01003 Serious 19100147 D04 I 09/26/2000 10/01/2000 $0 $2,500 $0 I - Informal Settlement Citation has been deleted.
4. 02001 Other 19100147 C06 II 09/26/2000 10/29/2000 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200965820
Event: 08/02/2000
Employee scalded by superheated oil and steam

Employee #1 was trying to melt solidified oil from the pump inlet without the cover in place. He had closed the valves to the pump, removed the face of the pump, and then noticed solidified oil in the pump housing. Employee #1 retrieved a torch with which to melt the oil so that he could remove the idler assembly and clean out the housing. He then cracked open the main steam line that was already attached to the block and bleed valve. Employee #1 fully opened the steam valve at the block and bleed valve, and then waited between 10 and 15 minutes before attempting to steam off the solid oil block at the inlet of the pump. He started to heat the 2 in. iron pipe to the inlet with the torch and within 5 minutes enough of the oil had melted so that the steam pressure, which had built up in the pipe, blew out the rest of the oil. Employee #1's arm was sprayed with 360 degrees F oil and steam. He sustained scalding burns, for which he was hospitalized.

Keywords: BURN, MAINTENANCE, STEAM, TORCH, HIGH PRESSURE, ARM, PUMP, PRESSURE RELEASE, HIGH TEMPERATURE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303852313 Hospitalized injury Burn/Scald(Heat) Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.