Inspection Detail
Inspection: 303824205 - Bello Painting Co.
Inspection Information - Office: Boston North Area Office
Site Address:
Bello Painting Co.
108 Broadway Street
Wakefield, MA 01880
Mailing Address:
P.O. Box 316, Milton, MA 02186
Union Status: Union
SIC:1721
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/23/2002
Emphasis:
Case Closed: 07/03/2003
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 200776474 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $1,200 | $0 | $0 | $0 | $0 | $1,200 |
Current Penalty | $1,200 | $0 | $0 | $0 | $0 | $1,200 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260021 B02 | 12/20/2002 | 12/26/2002 | $600 | $600 | $0 | - | ||
2. | 01002 | Serious | 19260102 A01 | 12/20/2002 | 12/26/2002 | $600 | $600 | $0 | - |
Investigation Summary
On August 20, 2002, Employee #1 was cleaning out a clogged spray tip on his spraying apparatus. He removed his protective goggles so he could see the tip better, and then activated the trigger while looking at the nozzle tip. The sprayer shot epoxy paint into both of his eyes, and onto the rest of his face. Employee #1 was transported to Melrose Wakefield Hospital, where he was treated and released that day.
Keywords: EYE, PPE, WORK RULES, CONSTRUCTION, SPRAY PAINTING, CLOGGED, PAINTER, ACCIDENTAL DISCHARGE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 303824205 | Non Hospitalized injury | Foreign Body Ineye | Painters, construction and maintenance |