Inspection Detail
Inspection: 303729974 - Conagra Beef Company
Inspection Information - Office: Omaha Area Office
Site Address:
Conagra Beef Company
3435 Gomez Road
Omaha, NE 68107
Mailing Address:
, , 00000
Union Status: Union
SIC:2011
NAICS: 0
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/16/2002
Emphasis: S:Amputations, S:Food Processing
Case Closed: 03/20/2002
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 200053064 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | 2 | |||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $2,125 | $0 | $0 | $0 | $0 | $2,125 |
| Current Penalty | $0 | $0 | $0 | $2,125 | $0 | $2,125 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Other | 19100335 A01 I | 02/22/2002 | 03/22/2002 | $2,125 | $2,125 | $0 | I - Informal Settlement | ||
| 2. | 02001 | Other | 19100132 D01 | 02/22/2002 | 03/22/2002 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
On January 15, 2001, Employee #1, a 40-year-old male, of Conagra Beef Company was assisting a coworker to troubleshoot a 480-volt power supply. The coworker was wearing hot gloves and a face shield, while Employee #1 was not wearing any PPE. Employee #1 was holding a voltmeter approximately 24 to 36 inches away from the coworker when the coworker touched a fuse with a lead from the voltmeter. Both employees reported seeing an arc at the panel box and in the voltmeter that employee #1 was holding. They also reported hearing a loud bang. Employee #1 received a shock that rendered him unconscious. Employee #1 regained consciousness within a few minutes, and was transported to a local hospital for treatment where he was released the same day. The suspected cause of the incident is a faulty voltmeter.
Keywords: BURN, ELEC PROTECT EQUIP, ELECTRIC ARC, ELECTRICAL TESTING, ELECTRICIAN, ELECTRICAL WORK, ELECTRIC METER, ELECTRICAL CABINET
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 303729974 | Hospitalized injury | Electric Shock | Electricians |
Translate