Powered by GoogleTranslate

Inspection Detail

Inspection: 303729834 - Dutton-Lainson Company

Inspection Information - Office: Omaha Area Office

 

Inspection Nr: 303729834
Report ID: 0728900
Date Opened: 01/09/2002

Site Address:
Dutton-Lainson Company
1601 West 2nd
Hastings, NE 68901

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3499

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/10/2002

Emphasis: N:Amputate, S:Amputations

Case Closed: 03/05/2002


Related Activity
Type Activity Nr Safety Health
Referral 200053049 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $6,375 $0 $0 $0 $0 $6,375
Current Penalty $3,506 $0 $0 $0 $0 $3,506
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100217 C02 IA 02/11/2002 03/01/2002 $2,250 $4,500 $0 I - Informal Settlement  
2. 01002 Serious 19100217 D01 II 02/11/2002 03/01/2002 $1,256 $1,875 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200051423
Event: 11/16/2001
Employee's finger amputated by mechanical power press

Employee #1 was operating a full-revolution mechanical power press. The press was equipped with point of operation guarding. The front of the press was guarded by an interlocked barrier gate that would allow the employee to hand feed the parts for the stamping and to retrieve the parts. The guard was designed to only allow the gate to be opened once a stroke was completed and the press was designed to cycle only with the gate closed. A piece of floor dry material had become lodged in the interlock switch which allowed the press to cycle with the gate open. Employee #1 placed a part on the die with a hand tool, closed the gate and observed that the part was not in the correct position. He then re-opened the gate and used his left hand to reposition the part. When reaching into the press, the employee inadvertently pressed the foot treadle and the press cycled amputating his left index finger.

Keywords: AMPUTATED, POWER PRESS, FINGER, GUARD, INTERLOCK, HAND TOOL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303729834 Hospitalized injury Amputation Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.