Inspection Detail
Inspection: 303684849 - The Trane Company
Inspection Information - Office: Corpus Christi Area Office
Site Address:
The Trane Company
4320 University Blvd
Laredo, TX 78041
Mailing Address:
3650 Highpoint, San Antonio, TX 78217
Union Status: Union
SIC:7623
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/11/2001
Emphasis:
Case Closed: 05/01/2003
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100211119 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 1 | 1 | 7 | ||
Current Violations | 5 | 1 | 1 | 7 | ||
Initial Penalty | $14,850 | $63,000 | $0 | $0 | $0 | $77,850 |
Current Penalty | $11,880 | $0 | $0 | $0 | $50,400 | $62,280 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100132 D01 | 12/11/2001 | 12/21/2001 | $1,080 | $1,350 | $0 | 01/04/2002 | F - Formal Settlement | |
2. | 01001B | Serious | 19100132 D02 | 12/11/2001 | 12/21/2001 | $0 | $0 | $0 | 01/04/2002 | F - Formal Settlement | |
3. | 01002A | Serious | 19100147 C04 II | 12/11/2001 | 12/21/2001 | $1,080 | $1,350 | $0 | 01/04/2002 | F - Formal Settlement | |
4. | 01002B | Serious | 19100147 C06 I | 12/11/2001 | 12/21/2001 | $0 | $0 | $0 | 01/04/2002 | F - Formal Settlement | |
5. | 01002C | Serious | 19100147 C06 II | 12/11/2001 | 12/21/2001 | $0 | $0 | $0 | 01/04/2002 | F - Formal Settlement | |
6. | 01002D | Serious | 19100147 C07 I | 12/11/2001 | 12/21/2001 | $0 | $0 | $0 | 01/04/2002 | F - Formal Settlement | |
7. | 01003 | Serious | 19100147 C05 I | 12/11/2001 | 12/21/2001 | $1,080 | $1,350 | $0 | 01/04/2002 | F - Formal Settlement | |
8. | 01004A | Serious | 19100332 B01 | 12/11/2001 | 12/21/2001 | $5,040 | $6,300 | $0 | 01/04/2002 | F - Formal Settlement | |
9. | 01004B | Serious | 19100335 A01 I | 12/11/2001 | 12/21/2001 | $0 | $0 | $0 | 01/04/2002 | F - Formal Settlement | |
10. | 01005 | Serious | 19101200 H01 | 12/11/2001 | 12/21/2001 | $3,600 | $4,500 | $0 | 01/04/2002 | F - Formal Settlement | |
11. | 02001A | Unclass | 19100333 C02 | 12/11/2001 | 12/21/2001 | $50,400 | $63,000 | $0 | 01/04/2002 | F - Formal Settlement | |
12. | 02001B | Unclass | 19100334 C01 | 12/11/2001 | 12/21/2001 | $0 | $0 | $0 | 01/04/2002 | F - Formal Settlement | |
13. | 03001 | Other | 19040002 B02 | 12/11/2001 | 12/14/2001 | $0 | $0 | $0 | 01/04/2002 | F - Formal Settlement |
Investigation Summary
A service technician for an air conditioning repair shop was replacing a bad motor on a variable air volume box. As he was working, he collapsed and later died. An autopsy found that the employee did not die of heart disease. The coroner observed a small burn mark on the employee's arm. The employee had apparently contacted an unprotected, energized fuse or terminal strip as he was repairing the motor. The employee had been electrocuted. (The autopsy indicated that the employee died of myocardial infarction from electric current passing through the heart.)
Keywords: REPAIR, E GI IV, ELECTRICAL, ELECTROCUTED, LOCKOUT, ELEC CIRC PART--MISC
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 303684849 | Fatality | Electric Shock | Occupation not reported |