Inspection Detail
Inspection: 303671689 - Western Concrete Pumping
Inspection Information - Office: Denver Area Office
Site Address:
Western Concrete Pumping
Wcr 59 And 16 1/2 Road
Keenesburg, CO 80643
Mailing Address:
1082 Denver Avenue, Loveland, CO 80537
Union Status: NonUnion
SIC:1771
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/25/2000
Emphasis: S:Construction, S:Construction Fatalities
Case Closed: 09/26/2001
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 101571347 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 1 | 1 | 2 | |||
Initial Penalty | $3,500 | $0 | $4,000 | $0 | $0 | $7,500 |
Current Penalty | $2,000 | $0 | $0 | $0 | $2,000 | $4,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260416 A03 | 09/26/2000 | 10/02/2000 | $1,500 | $1,500 | $0 | 12/04/2000 | F - Formal Settlement | Citation has been deleted. |
2. | 01002 | Serious | 19260600 A06 | 09/26/2000 | 05/13/2001 | $2,000 | $2,000 | $0 | 12/04/2000 | F - Formal Settlement | |
3. | 02001 | Unclass | 19260021 B02 | 09/26/2000 | 03/10/2001 | $2,000 | $4,000 | $0 | 12/04/2000 | F - Formal Settlement |
Investigation Summary
An employee was operating a concrete pumping truck by a remote control box strapped to his chest. The truck was parked approximately 7.6 meters from a 7620-volt overhead power line. A city employee located across the embankment yelled to the operator that his boom was too close to the power line. In spite of the warning, the boom contacted the power line, and the concrete pumping truck operator was electrocuted. The city employee ran to the operator to remove the control harness from his body. The city employee received an electric shock. The city employee was air lifted to a hospital, where he was admitted and treated for his injuries. The operator had worked for the company for 4 months. He had had on-the-job training on the operation of the pumping truck. Operator's manuals warning against operating the boom within 5.2 meters of overhead power lines was located in the truck. (The city employee was listed on an injury line under the inspection number for the concrete contractor.)
Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CONCRETE TRUCK, ELECTROCUTED, E C, ELECTRIC SHOCK
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 303671689 | Fatality | Electric Shock | Occupation not reported | ||
2 | 303671689 | Hospitalized injury | Electric Shock | Occupation not reported |