Powered by GoogleTranslate

Inspection Detail

Inspection: 303646186 - Triple L Construction

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 303646186
Report ID: 0627700
Date Opened: 08/24/2001

Site Address:
Triple L Construction
421 South Mayes
Adair, OK 74330

Mailing Address:
3646 Apple Valley Road, Van Buren, AR 72956

Union Status: NonUnion

SIC:1542

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/06/2001

Emphasis: L:Fall, S:Construction, S:Construction Fatalities

Case Closed: 05/10/2002


Related Activity
Type Activity Nr Safety Health
Accident 100642297
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3 6
Current Violations 2 2 4
Initial Penalty $2,550 $0 $0 $1,500 $0 $4,050
Current Penalty $1,050 $0 $0 $0 $0 $1,050
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260351 B03 10/16/2001 10/20/2001 $450 $450 $0 11/09/2001 F - Formal Settlement  
2. 01001B Serious 19260351 B04 10/16/2001 10/20/2001 $0 $0 $0 11/09/2001 F - Formal Settlement  
3. 01002A Serious 19260404 B01 I 10/16/2001 10/20/2001 $0 $1,500 $0 11/09/2001 F - Formal Settlement Citation has been deleted.
4. 01002B Serious 19260404 F06 10/16/2001 10/20/2001 $0 $0 $0 11/09/2001 F - Formal Settlement Citation has been deleted.
5. 01002C Serious 19260416 E01 10/16/2001 10/20/2001 $0 $0 $0 11/09/2001 F - Formal Settlement Citation has been deleted.
6. 01003A Serious 19260451 B01 10/16/2001 10/20/2001 $600 $600 $0 11/09/2001 F - Formal Settlement  
7. 01003B Serious 19260451 G01 10/16/2001 10/20/2001 $0 $0 $0 11/09/2001 F - Formal Settlement  
8. 02001 Other 19040008 10/16/2001 10/20/2001 $1,500 $1,500 $0 11/09/2001 F - Formal Settlement Citation has been deleted.
9. 02002 Other 19260404 E01 I 10/16/2001 10/20/2001 $0 $0 $0 11/09/2001 F - Formal Settlement  
10. 02003 Other 19260405 G02 III 10/16/2001 10/20/2001 $0 $0 $0 11/09/2001 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200642031
Event: 08/22/2001
One employee killed, one injured in electric shock and fall

On August 22, 2001, Employees #1 and #2, of Triple L Construction, were using a mobile scaffold to raise the center ridge beams of a lightweight metal building that was to be used as a church. Employee #1 was using an angle grinder that required both hands to hold and operate. Employee #2 had just climbed the scaffold and connected the grinder attachment cord to his electric cord set. Employee #1 then grasped the back of the grinder with his left hand to operate the switch and held the projecting metal handle on the right side of the grinder head with his right hand. He had activated the grinder when he suddenly swung into Employee #2, who tried to hold both of them and grabbed the scaffold, resulting in his being shocked. Both employees fell approximately 14 ft from the scaffold platform onto the concrete floor. Employee #1 landed in a sitting position; Employee #2 caught the scaffold cross-bracing on the way down, breaking his fall. Both workers were immediately transported to the hospital. Employee #1 was declared dead shortly after arrival, and Employee #2 was treated and released. Subsequent examination of the grinder, connected cord sets, and the temporary electrical service found several deficiencies that could lead to electrical shock. The grinder had a nick in the insulation exposing the neutral conductor. The cord set immediately attached to the grinder had, about 10 ft from the grinder connection, had a 1 in. area where the insulation was missing, exposing both the energized and neutral conductors. It was also missing the ground pin from the male attachment plug, disrupting the grounding continuity and potentially allowing reverse polarity. An intermediary cord set was also missing a ground pin. The ground fault circuit interrupter (GFCI) portion of the circuit breaker was not connected, thus rendering the GFCI inoperative. In addition, the scaffold did not have guardrails nor was any other form of fall protection provided.

Keywords: GRINDER, INADEQUATE MAINT, INSULATED TOOL, WORK RULES, CONSTRUCTION, ELEC CIRC PART--MISC, ELECTRIC SHOCK, FALL, FALL PROTECTION, ELECTRIC CORD

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303646186 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported
2 303646186 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.