Powered by GoogleTranslate

Inspection Detail

Inspection: 303641872 - Big Horn Towers Inc.

Inspection Information - Office: Oklahoma City Area Office

 

Inspection Nr: 303641872
Report ID: 0627700
Date Opened: 03/08/2001

Site Address:
Big Horn Towers Inc.
2.7 Mi. West Of City
Wilson, OK 73463

Mailing Address:
2801 Howard Court, Denton, TX 76209

Union Status: NonUnion

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/14/2001

Emphasis: L:Fall, S:Construction Fatalities

Case Closed: 05/08/2002


Related Activity
Type Activity Nr Safety Health
Accident 100642032
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $4,500 $0 $0 $0 $0 $4,500
Current Penalty $4,500 $0 $0 $0 $0 $4,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260021 B02 06/12/2001 06/20/2001 $1,500 $1,500 $0 -  
2. 01002 Serious 19260552 A01 06/12/2001 06/20/2001 $1,500 $1,500 $0 -  
3. 01003 Serious 19260552 B01 II 06/12/2001 06/20/2001 $1,500 $1,500 $0 -  

Investigation Summary

Investigation Nr: 200641769
Event: 03/07/2001
Employee falls from tower and dies

At approximately 3:50 p.m. on March 7, 2001, Employee #1, a crew leader, and three coworkers were replacing a 1.625 in. coax cable on the top of a 400 ft wire guy tower. After climbing the tower, Employee #1 tied off to the electrical capstan hoist load line. In the process of riding the line down, cable snap-ins were removed that secured the old cable to the side of the tower. On the ground, the new cable was tied to the hoist line and Employee #1 rode the hoist load line back up to the top of the tower, where the new cable was temporarily secured. The old cable was tied in to the hoist line at the top of the tower and Employee #1 got on the hoist load line and signaled the trainee hoist operator to lower the line. Employee #1 and old cable were lowered about 20 ft when the line stopped sliding around the drum of the capstan hoist. The trainee hoist operator was instructed to remove one of six wraps of rope from the drum. In attempting to remove a wrap the rope line came off the hoist drum, and Employee #1 and the old cable fell from near the top of the tower to the ground. Employee #1 died.

Keywords: DRUM HOIST, HOISTING MECHANISM, WIRE ROPE, DRUM, HOIST, FALL, LOAD LINE, HOISTLINE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303641872 Fatality Concussion Electrical power installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close