Powered by GoogleTranslate

Inspection Detail

Inspection: 303614937 - Tyco Electonics

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 303614937
Report ID: 0854910
Date Opened: 02/27/2001

Site Address:
Tyco Electonics
710 N 600 W
Logan, UT 84321

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3672

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/06/2001

Planning Guide: Safety-Manufacturing

Emphasis: S:Amputations, S:Manufacturing

Case Closed: 07/05/2001


Related Activity
Type Activity Nr Safety Health
Accident 362653438
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $500 $0 $500
Current Penalty $0 $0 $0 $500 $0 $500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 10005 C02 04/18/2001 04/22/2001 $500 $500 $0 -  
2. 01002 Other 19100133 A01 04/18/2001 04/24/2001 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 171060619
Event: 02/26/2001
Chemist Burned By Acid

Employee #1, a chemist, was burned on her face and neck by acid when the hoist came in contact with the container. The electrolysis process is where the copper plates are placed in several tanks to be coated. The copper plates are moved from tank to tank by hoists. The lab technicians check the various tanks at least once per shift. The sulfuric acid tank is checked and brought up to a concentration of 17, so that they can maintain an approximate concentration of 15. Sulfuric acid with a concentration of 96 is typically used. The technicians added between 0.25 and 3.5 gallons of sulfuric acid to the tanks when needed to reach the proper concentration. The technician was in the process of pouring acid into the tank. As the hoists are raised to move the plates, a rotating light on each hoist is activated. The technician stated that she misjudged the distance of the hoist. The hoist came into contact with the container, causing acid to spill on her face and neck. Employee #1 went to a local hospital for treatment.

Keywords: BURN, SULFURIC ACID

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303614937 Hospitalized injury Burn(Chemical) Chemists, except biochemists
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close