Powered by GoogleTranslate

Inspection Detail

Inspection: 303612824 - Interstate Erectors

Inspection Information - Office: Utah Division Of Occupational Safety And Health

 

Inspection Nr: 303612824
Report ID: 0854910
Date Opened: 12/07/2000

Site Address:
Interstate Erectors
138 W 300 S
Salt Lake City, UT 84101

Mailing Address:
586 Fine Drive, Slc, UT 84115

Union Status: NonUnion

SIC:1791

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/27/2001

Planning Guide: Safety-Construction

Emphasis: S:Construction, S:Construction Fatalities

Case Closed: 11/27/2006


Related Activity
Type Activity Nr Safety Health
Accident 362653107
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $1,350 $21,000 $0 $0 $0 $22,350
Current Penalty $1,350 $21,000 $0 $0 $0 $22,350
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Willful 19260416 A01 03/15/2001 03/21/2001 $21,000 $21,000 $0 -  
2. 02001 Serious 19260750 B01 II 03/15/2001 03/21/2001 $1,350 $1,350 $0 -  

Investigation Summary

Investigation Nr: 171060288
Event: 12/07/2000
Electric Shock - Contact with Overhead Line thru Angle Iron

Three employees were moving 6.1-meter-long pieces of angle iron (truss supports) to the roof area of a building under construction. One employee was on ground level; one was on the metal pan stairs, about 6.1 meters above the ground; and the other one was in a sitting position, straddling a steel I-beam that was 12.6 meters above the ground. A phase conductor for a 7200-volt overhead power line was located 3.4 meters horizontally from the center of the beam. The neutral conductor was about 75 millimeters higher and 2.6 meters from the center of the beam. The employee sitting on the beam brought an angle iron into contact with the phase conductor and was electrocuted.

Keywords: METAL RAIL, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E C

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303612824 Fatality Electric Shock Structural metal workers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close