Inspection Detail
Inspection: 303610208 - Fairchild Semi Conductor (Nsc)
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Fairchild Semi Conductor (Nsc)
3333 W 9000 S
West Jordan, UT 84088
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3674
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/29/2000
Planning Guide: Safety-Manufacturing
Emphasis: S:Amputations, S:Manufacturing
Case Closed: 09/29/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 362652620 |
Investigation Summary
Employee #1 was trying to reset the spin on glass (sog) track that was sticking when her glove became caught on the chuck. Her fingers were pulled into the machine's pinch point, sustaining injuries that required hospitalization.
Keywords: CLOTHING, FINGER, GLOVE, STUCK, WORK RULES, CAUGHT BY, POINT OF OPERATION, UNGUARDED
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 303610208 | Hospitalized injury | Fracture | Machine operators, not specified |
Translate