Inspection Detail
Inspection: 303573547 - Jervis B Webb Company
Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation
Site Address:
Jervis B Webb Company
156 Webb Forging Road
Carlisle, SC 29031
Mailing Address:
34375 W 12 Mile Road, Farmington Hills, MI 48331
Union Status: Union
SIC:3462
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/11/2002
Emphasis:
Case Closed: 04/02/2003
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100373380 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 6 | 2 | 8 | |||
| Current Violations | 2 | 2 | 4 | |||
| Initial Penalty | $8,400 | $0 | $0 | $0 | $0 | $8,400 |
| Current Penalty | $1,200 | $0 | $0 | $0 | $0 | $1,200 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100217 B07 III | 07/24/2002 | 08/26/2002 | $600 | $1,500 | $0 | 08/14/2002 | F - Formal Settlement | |
| 2. | 01002 | Serious | 19100217 C02 III | 07/24/2002 | 07/29/2002 | $1,200 | $1,200 | $0 | 08/14/2002 | F - Formal Settlement | Citation has been deleted. |
| 3. | 01003 | Serious | 19100217 C03 IIIF | 07/24/2002 | 07/29/2002 | $1,200 | $1,200 | $0 | 08/14/2002 | F - Formal Settlement | Citation has been deleted. |
| 4. | 01004 | Serious | 19100217 C03 IVB | 07/24/2002 | 07/30/2002 | $1,500 | $1,500 | $0 | 08/14/2002 | F - Formal Settlement | Citation has been deleted. |
| 5. | 01005 | Serious | 19100217 C04 | 07/24/2002 | 08/26/2002 | $1,500 | $1,500 | $0 | 08/14/2002 | F - Formal Settlement | Citation has been deleted. |
| 6. | 01006 | Serious | 19100217 C05 I | 07/24/2002 | 08/26/2002 | $1,500 | $1,500 | $0 | 08/14/2002 | F - Formal Settlement | Citation has been deleted. |
| 7. | 01007A | Serious | 19100217 C02 III | 07/24/2002 | 07/29/2002 | $600 | $0 | $0 | Q - National Office Adjustment | ||
| 8. | 01007B | Serious | 19100217 C03 III | 07/24/2002 | 07/29/2002 | $0 | $0 | $0 | F - Formal Settlement | ||
| 9. | 02001 | Other | 19100147 C04 II | 07/24/2002 | 08/26/2002 | $0 | $0 | $0 | 08/14/2002 | F - Formal Settlement | |
| 10. | 02002 | Other | 19100147 C06 II | 07/24/2002 | 08/05/2002 | $0 | $0 | $0 | 08/14/2002 | F - Formal Settlement |
Investigation Summary
At 8:30 a.m. on June 13, 2002, Employee #1 was placing a part into a Minister 90-600 part revolution press. The pullbacks failed to pull his hands back in time due to improper adjustment. The press cycled on him while his hands were in the point of operation. Employee #1 was hospitalized for a pinching injury to a finger.
Keywords: POWER PRESS, FINGER, POINT OF OPERATION, HAND, PRESS
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 303573547 | Hospitalized injury | Bruise/Contus/Abras | Machinists |
Translate