Powered by GoogleTranslate

Inspection Detail

Inspection: 303568497 - Fluor-Global Services

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 303568497
Report ID: 0454510
Date Opened: 03/20/2002

Site Address:
Fluor-Global Services
4001 Mccords Ferry Rd
Eastover, SC 29044

Mailing Address:
100 Fluor-Daniel Dr., Greenville, SC 29607

Union Status: NonUnion

SIC:1796

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 04/16/2002

Emphasis:

Case Closed: 08/26/2002


Related Activity
Type Activity Nr Safety Health
Accident 100373208
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $1,500 $0 $0 $0 $0 $1,500
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19101200 H01 05/02/2002 06/04/2002 $1,500 $1,500 $0 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200372118
Event: 03/17/2002
Three employees exposed to chemical vapors

At approximately 5:20 a.m. on March 17, 2002, Employees #1, #2, and #3, pulp mill technicians, were draining towers in the bleach mill to the sewer during outage. A washer overflowed and released a large amount of residual chlorine dioxide gas. Employees #1, #2 and #3 were working on another tank approximately 180 feet away. They smelled the gas, left the area, and called a supervisor. The area was monitored and levels were returned to normal. The employees went home, but continued to exhibit symptoms. The employees returned to work the next day and were transported to the emergency room where they were treated and released. The three employees are contract employees used during outages.

Keywords: SEWER, BLEACH, INHALATION, GAS, CHLORINE DIOXIDE, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303568497 Non Hospitalized injury Other Supervisors; plumbers, pipefitters & steamfitters
2 303568497 Non Hospitalized injury Other Supervisors; plumbers, pipefitters & steamfitters
3 303568497 Non Hospitalized injury Other Supervisors; plumbers, pipefitters & steamfitters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close