Powered by GoogleTranslate

Inspection Detail

Inspection: 303557862 - Gold Kist Inc. Sc Poultry Div.

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 303557862
Report ID: 0454510
Date Opened: 08/23/2001

Site Address:
Gold Kist Inc. Sc Poultry Div.
2050 Hwy. 15 South
Sumter, SC 29150

Mailing Address:
P O Box 2210, Atlanta, GA 30346

Union Status: NonUnion

SIC:2015

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 10/09/2001

Planning Guide: Health-Manufacturing

Emphasis:

Case Closed: 03/18/2004


Related Activity
Type Activity Nr Safety Health
Accident 100372606
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $5,000 $0 $0 $0 $0 $5,000
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 10012 A 10/18/2001 11/13/2001 $5,000 $5,000 $0 11/03/2001 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200371813
Event: 08/07/2001
Employee Injured When Using Cooker

At approximately 3:50 p.m. on August 7, 2001, Employee #1 was attempting to open the door of a feather cooker when steam and feather meal erupted through the door. Employee #1 did not have a flat metal shield in place in front of the door and he suffered second and third degree burns over approximately 10 to 12 percent of the body. It was determined that the cooker's "bleed-off" valve was not working properly. This was due to the fact that the vent line and valve were almost completely clogged by feather meal. The employer had no established guidelines for routinely checking or cleaning the vent lines. Employee #1 was hospitalized.

Keywords: BURN, HEAT, SAFETY RELIEF VALVE, COOKER, EQUIPMENT FAILURE, STEAM

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303557862 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close