Inspection Detail
Inspection: 303531305 - Sibling Management
Inspection Information - Office: Queens District Office
Site Address:
Sibling Management
68-64 Yellowstone Blvd.
Forest Hills, NY 11375
Mailing Address:
2607 Nostrand Avenue, Brooklyn, NY 11210
Union Status: NonUnion
SIC:6531
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/07/2002
Emphasis:
Case Closed: 05/09/2002
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100830371 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 1 | 4 | |||
Current Violations | 3 | 1 | 4 | |||
Initial Penalty | $1,800 | $0 | $0 | $0 | $0 | $1,800 |
Current Penalty | $1,800 | $0 | $0 | $0 | $0 | $1,800 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100132 F01 | 02/08/2002 | 04/28/2002 | $600 | $600 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100304 F04 | 02/08/2002 | 02/13/2002 | $600 | $600 | $0 | I - Informal Settlement | ||
3. | 01003 | Serious | 19100305 G02 III | 02/08/2002 | 02/13/2002 | $600 | $600 | $0 | I - Informal Settlement | ||
4. | 02001A | Other | 19101200 E01 | 02/08/2002 | 04/28/2002 | $0 | $0 | $0 | I - Informal Settlement | ||
5. | 02001B | Other | 19101200 G08 | 02/08/2002 | 04/28/2002 | $0 | $0 | $0 | I - Informal Settlement | ||
6. | 02001C | Other | 19101200 H | 02/08/2002 | 04/28/2002 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 was a building superintendent who was unclogging the drains in an unused decorative fountain the day after it rained. He was using an electric snake while standing barefoot in approximately a foot and a half of water that had accumulated in the fountain. The ground prongs on both the electric drain opener and the twenty-foot extension cord were missing. In addition, the tool was plugged into an ungrounded outlet. He was electrocuted.
Keywords: E GI V, E GI III, ELECTRICAL, INADEQUATE MAINT, DRAIN PIPE, CORD SET, ELECTROCUTED, EQUIPMENT GROUNDING, PLUMBING, ELEC PORT TOOL--MISC
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 303531305 | Fatality | Electric Shock | Occupation not reported |