Inspection Detail
Inspection: 3035292 - Revco Scientific, Inc.
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Revco Scientific, Inc.
275 Aiken Road
Weaverville, NC 28787
Mailing Address:
, , 00000
Union Status: NonUnion
SIC:3585
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/19/1989
Emphasis:
Case Closed: 10/31/1989
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360487482 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
Current Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19101200 H02 III | 10/13/1989 | 10/19/1989 | $420 | $420 | $0 | - |
Investigation Summary
A flash fire from a regulator in which Employee #1 was standing in front of, was intensified by escaping oxygen from a tank. Employee #1 was hospitalized for severe third degree burns to her arms, hands, and abdomen.
Keywords: BURN, OXYGEN, ABDOMEN, REGULATOR VALVE, FIRE, ARM, HAND
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 3035292 | Hospitalized injury | Burn/Scald(Heat) | Solderers and brazers |