Powered by GoogleTranslate

Inspection Detail

Inspection: 303212583 - Ex-L-Tube, Inc.

Inspection Information - Office: Kansas City Area Office

 

Inspection Nr: 303212583
Report ID: 0728500
Date Opened: 02/20/2001

Site Address:
Ex-L-Tube, Inc.
905 Atlantic Street
North Kansas City, MO 64116

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:3498

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/27/2001

Emphasis:

Case Closed: 07/24/2001


Related Activity
Type Activity Nr Safety Health
Accident 100001296
Referral 200005858 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 5 2 7
Initial Penalty $7,965 $0 $0 $0 $0 $7,965
Current Penalty $6,465 $0 $0 $0 $0 $6,465
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100023 D01 III 06/27/2001 02/21/2001 $765 $765 $0 I - Informal Settlement  
2. 01002 Other 19100147 F03 II 06/27/2001 07/10/2001 $0 $1,500 $0 I - Informal Settlement  
3. 01003 Serious 19100212 A01 06/27/2001 07/17/2001 $1,200 $1,200 $0 I - Informal Settlement  
4. 01004 Serious 19100303 H03 I 06/27/2001 08/14/2001 $1,500 $1,500 $0 I - Informal Settlement  
5. 01005 Serious 19100333 A 06/27/2001 07/17/2001 $1,500 $1,500 $0 I - Informal Settlement  
6. 01006 Serious 19100335 A02 II 06/27/2001 07/17/2001 $1,500 $1,500 $0 I - Informal Settlement  
7. 02001 Other 19100306 G02 IV 06/27/2001 07/17/2001 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200001170
Event: 02/12/2001
Electric Shock - Direct Contact with Energized Parts

Some maintenance electricians had replaced the contact rings on the bottom of an oscillating tube for a Thermatool welder. The maintenance supervisor removed lockout devices, and the welding machine was reenergized. The maintenance supervisor and two electricians were standing on the side of the welding machine, observing energized parts with the outer door removed and the machine running. One of the electricians stepped forward, contacted a circuit part that was energized at 25 to 27 kilovolts, DC, and was electrocuted. He had not been using any personal protective equipment.

Keywords: ELEC PROTECT EQUIP, MAINTENANCE, E GI III, ELECTRICAL, ELECTRICIAN, ELECTROCUTED, ELECTRICAL WORK, ELEC CIRC PART--MISC

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 303212583 Fatality Electric Shock Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close