Powered by GoogleTranslate

Inspection Detail

Inspection: 3029436 - Ruby Collins Inc

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 3029436
Report ID: 0453710
Date Opened: 09/22/1986

Site Address:
Ruby Collins Inc
1200 Queens Road
Charlotte, NC 28207

Mailing Address:
P O Box 19306, Charlotte, NC 28219

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/23/1986

Emphasis:

Case Closed: 12/09/1986


Related Activity
Type Activity Nr Safety Health
Accident 360767669
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $360 $0 $0 $0 $0 $360
Current Penalty $360 $0 $0 $0 $0 $360
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260550 A15 I 10/13/1986 10/16/1986 $360 $360 $0 -  

Investigation Summary

Investigation Nr: 14250799
Event: 09/19/1986
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BACKHOE

A HITACHI BACKHOE (NUMBER UH261) WAS BEING USED TO MOVE A METAL PIPE. AN EMPLOYEE WAS HOLDING THE PIPE TO GUIDE IT INTO POSITION. THE BOOM OF THE BACKHOE CAME TOO CLOSE TO A 7200-VOLT OVERHEAD POWER LINE, CAUSING AN ELECTRIC ARC. THE EMPLOYEE HOLDING THE PIPE WAS KNOCKED TO THE GROUND. ARTIFICIAL RESPIRATION WAS QUICKLY PROVIDED BY OTHERS ON THE SITE. THE EMPLOYEE WAS REVIVED AND TAKEN TO THE HOSPITAL, WHERE HE WAS RELEASED AFTER 3 DAYS.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, E C, ELECTRIC SHOCK, BACKHOE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 3029436 Hospitalized injury Electric Shock Construction trades, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close