Powered by GoogleTranslate

Inspection Detail

Inspection: 302923149 - Cameo Enterprises Incorporated

Inspection Information - Office: Boston South Area Office

 

Inspection Nr: 302923149
Report ID: 0111400
Date Opened: 08/24/2000

Site Address:
Cameo Enterprises Incorporated
Nook Road
Plymouth, MA 02360

Mailing Address:
50 Durby Street, Hingham, MA 02043

Union Status: Union

SIC:1794

NAICS: 0 


Inspection Type: Referral

Scope: Complete

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/12/2000

Emphasis: N:Trench

Case Closed: 03/02/2001


Related Activity
Type Activity Nr Safety Health
Referral 200465490 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $18,000 $0 $0 $0 $0 $18,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260251 B01 09/19/2000 09/22/2000 $1,200 $1,200 $0 I - Informal Settlement  
2. 01002 Serious 19260550 A15 II 09/12/2000 09/15/2000 $4,200 $4,200 $0 I - Informal Settlement  
3. 01003 Serious 19260651 C02 09/12/2000 09/15/2000 $4,200 $4,200 $0 I - Informal Settlement  
4. 01004 Serious 19260651 K01 09/12/2000 09/15/2000 $4,200 $4,200 $0 I - Informal Settlement  
5. 01005 Serious 19260652 A01 09/12/2000 09/15/2000 $4,200 $4,200 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 200460830
Event: 08/24/2000
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM

Some employees were installing ductile iron pipe. Two of the employees were holding and guiding the pipe as an excavator moved it into position. The excavator contacted a 2400-volt overhead power line. Both employees received electric shocks, and one of them lost consciousness. A passing emergency medical services team received the emergency call and provided medical assistance. The team used a defibrillator and revived the unconscious worker, who was hospitalized for his injuries.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, CPR, CONSTRUCTION, E C, ELECTRIC SHOCK, EXCAVATOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302923149 Non Hospitalized injury Electric Shock Construction laborers
2 302923149 Hospitalized injury Electric Shock Construction laborers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.