Inspection Detail
Inspection: 302874334 - R L Dresser Inc
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
R L Dresser Inc
George Daniels Rd. & Old Cementary Rd.
Manteo, NC 27954
Mailing Address:
Pob 17086, Raleigh, NC 27619
Union Status: NonUnion
SIC:1799
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/10/1999
Planning Guide: Safety-Construction
Emphasis: S:Construction Fatalities, S:Program Improvements
Case Closed: 04/20/2001
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100352442 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 9 | 14 | |||
Current Violations | 5 | 5 | 10 | |||
Initial Penalty | $17,500 | $0 | $0 | $3,000 | $0 | $20,500 |
Current Penalty | $14,875 | $0 | $0 | $3,000 | $0 | $17,875 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 95012901 | 02/23/2000 | 03/27/2000 | $3,500 | $3,500 | $0 | 06/13/2000 | W - Empr Withdrew | |
2. | 01002 | Serious | 19260152 F03 | 02/23/2000 | 02/28/2000 | $3,500 | $3,500 | $0 | 06/13/2000 | W - Empr Withdrew | |
3. | 01003A | Serious | 19260150 C01 VI | 02/23/2000 | 03/27/2000 | $0 | $3,500 | $0 | 06/13/2000 | F - Formal Settlement | Citation has been deleted. |
4. | 01003B | Serious | 19260150 A01 | 02/23/2000 | 03/27/2000 | $2,625 | $0 | $0 | 06/13/2000 | F - Formal Settlement | |
5. | 01004 | Serious | 19260103 E08 | 02/23/2000 | 03/27/2000 | $2,625 | $3,500 | $0 | 06/13/2000 | F - Formal Settlement | |
6. | 01005 | Serious | 19260021 B02 | 02/23/2000 | 03/27/2000 | $2,625 | $3,500 | $0 | 06/13/2000 | F - Formal Settlement | |
7. | 02001 | Other | 19040008 | 02/23/2000 | 03/12/2000 | $3,000 | $3,000 | $0 | 06/13/2000 | W - Empr Withdrew | |
8. | 02002 | Other | 19260050 B | 02/23/2000 | 03/12/2000 | $0 | $0 | $0 | 06/13/2000 | W - Empr Withdrew | |
9. | 02003 | Other | 19260095 A | 02/23/2000 | 03/27/2000 | $0 | $0 | $0 | 06/13/2000 | W - Empr Withdrew | |
10. | 02004 | Other | 19260102 A01 | 02/23/2000 | 03/27/2000 | $0 | $0 | $0 | 06/13/2000 | W - Empr Withdrew | |
11. | 02005 | Other | 19260103 E01 | 02/23/2000 | 03/27/2000 | $0 | $0 | $0 | 06/13/2000 | W - Empr Withdrew | |
12. | 02006 | Other | 19101200 G08 | 02/23/2000 | 02/28/2000 | $0 | $0 | $0 | 06/13/2000 | F - Formal Settlement | Citation has been deleted. |
13. | 02007 | Other | 19101200 H | 02/23/2000 | 03/27/2000 | $0 | $0 | $0 | 06/13/2000 | F - Formal Settlement | Citation has been deleted. |
14. | 02008 | Other | 19101200 H01 III | 02/23/2000 | 03/12/2000 | $0 | $0 | $0 | 06/13/2000 | F - Formal Settlement | Citation has been deleted. |
15. | 02009 | Other | 19101200 H02 II | 02/23/2000 | 03/12/2000 | $0 | $0 | $0 | 06/13/2000 | F - Formal Settlement | Citation has been deleted. |
Investigation Summary
Employees #1 and two coworkers were applying C1010 primer to a gym floor. There were two Vulcan industrial gas stoves in the room next to the gym, and the stoves had a total of twelve pilot lights. The vapors from the primer apparently reached the open flames of the pilot lights and ignited, resulting in an explosion and flashover. Employee #1 sustained fatal burns and one coworker suffered first- and second-degree burns over 20 to 30 percent of his body.
Keywords: BURN, PILOT LIGHT, VAPOR, VENTILATION, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, EXPLOSION, PAINT SOLVENT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 302874334 | Fatality | Burn/Scald(Heat) | Occupation not reported |