Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 11/27/2000

Emphasis: L:Fall

Case Closed: 01/08/2001


Related Activity
Type Activity Nr Safety Health
Accident 100540251
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $13,050 $0 $0 $0 $0 $13,050
Current Penalty $13,050 $0 $0 $0 $0 $13,050
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100132 A 11/28/2000 12/01/2000 $4,500 $4,500 $0 -  
2. 01001B Serious 19100132 D01 11/28/2000 12/01/2000 $0 $0 $0 I - Informal Settlement Citation has been deleted.
3. 01001C Serious 19100132 F01 11/28/2000 12/01/2000 $0 $0 $0 I - Informal Settlement Citation has been deleted.
4. 01002 Serious 19100178 L01 I 11/28/2000 12/01/2000 $2,250 $2,250 $0 -  
5. 01003A Serious 19100333 A01 11/28/2000 12/01/2000 $6,300 $6,300 $0 -  
6. 01003B Serious 19100333 C03 IA1 11/28/2000 12/01/2000 $0 $0 $0 -  
7. 01003C Serious 19100333 C07 11/28/2000 12/01/2000 $0 $0 $0 I - Informal Settlement Citation has been deleted.
8. 01003D Serious 19100333 C06 11/28/2000 12/01/2000 $0 $0 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 200540573
Event: 10/03/2000
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LADDER

A temporary employee was removing a vent pipe from the outside of a building. He was using a 6.1-meter section from a metal extension ladder. A 7200-volt overhead power line was located about 6.4 meters above the ground and 2.5 meters from the metal wall of the building. As the employee was maneuvering the ladder, it contacted the power line, and the employee was electrocuted. His body was found about 2 to 3 hours after the employee was last seen.

Keywords: EXTENSION LADDER, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, METAL LADDER, E GI IB

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302815949 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.