Inspection Detail
Inspection: 302729835 - Oberto Sausage Co
Inspection Information - Office: Eugene
Site Address:
Oberto Sausage Co
850 Sw 30th
Albany, OR 97321
Mailing Address:
1211 Sw Fifth Ave Stes 1600-1950, Portland, OR 97204
Union Status: NonUnion
SIC:2013
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/15/2000
Planning Guide: Health-Manufacturing
Emphasis:
Case Closed: 09/20/2000
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
Current Penalty | $1,500 | $0 | $0 | $0 | $0 | $1,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19101200 F05 I | 05/23/2000 | 05/26/2000 | $500 | $500 | $0 | - | ||
2. | 01002 | Serious | 702022104 D | 05/23/2000 | 05/26/2000 | $500 | $500 | $0 | - | ||
3. | 01003A | Serious | 19101200 H03 II | 05/23/2000 | 06/19/2000 | $500 | $500 | $0 | P - Petition to Mod Abatement | ||
4. | 01003B | Serious | 19101200 H03 III | 05/23/2000 | 06/19/2000 | $0 | $0 | $0 | P - Petition to Mod Abatement |
Investigation Summary
Employee #1 was cleaning screens in the wash room when a Smokecraft employee opened the sanitation cage and pumped "Quorum Green" into a 2.5 gallon bucket which had been used to contain the incompatible chemical "Dari-San". Residue of the chemical was still in the bucket. A reaction took place in the bucket which gave off a foul odor. The employee immediately disposed of the contents down the drain. In the process, gas or vapors escaped to the room occupied by Employee #1, and were directed towards him by an electrical fan. Employee #1 inhaled the vapors or gases and experienced respiratory problems, vomiting, numbness, and shaking. Employee #1 was transferred by ambulance to Albany General Hospital for treatment and was released 15 hours later.
Keywords: RESPIRATORY, FAN, SCREEN, INHALATION, GAS, CHEMICAL REACTION, CHEMICAL VAPOR, CHEMICAL, VOMIT
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 302729835 | Hospitalized injury | Burn(Chemical) | Occupation not reported |