Inspection Detail
Inspection: 302715628 - Solutia
Inspection Information - Office: Marlton Area Office
Site Address:
Solutia
Rte. 130 South
Bridgeport, NJ 08014
Mailing Address:
P.O. Box 309, Bridgeport, NJ 08014
Union Status: NonUnion
SIC:2899
NAICS: 0
Inspection Type: Complaint
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/27/2000
Emphasis:
Case Closed: 08/15/2000
Type | Activity Nr | Safety | Health |
---|---|---|---|
Complaint | 203013396 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $4,500 | $0 | $0 | $0 | $0 | $4,500 |
Current Penalty | $3,375 | $0 | $0 | $0 | $0 | $3,375 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100132 A | 08/01/2000 | 08/09/2000 | $3,375 | $4,500 | $0 | I - Informal Settlement |
Investigation Summary
Employee #1 received second-and-third-degree burns over 45 percent of his body when boiling water was ejected from a tank he was looking into. The water came out of the tank because of an expanding bubble of nitrogen that had been injected into the tank. Employee #1 was hospitalized.
Keywords: BURN, HEAT, NITROGEN, TANK, WATER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 302715628 | Hospitalized injury | Burn/Scald(Heat) | Machine operators, not specified |