Inspection Detail
Inspection: 302710389 - Bally'S Park Place
Inspection Information - Office: Marlton Area Office
Site Address:
Bally'S Park Place
Park Place & Boardwalk
Atlantic City, NJ 08401
Mailing Address:
, , 00000
Union Status: Union
SIC:7011
NAICS: 0
Inspection Type: Unprog Rel
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 12/06/1999
Emphasis:
Case Closed: 07/28/2000
Type | Activity Nr | Safety | Health |
---|---|---|---|
Inspection | 302710413 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $5,000 | $0 | $0 | $0 | $0 | $5,000 |
Current Penalty | $1,000 | $0 | $0 | $0 | $0 | $1,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100146 C06 | 12/08/1999 | 01/10/2000 | $1,000 | $5,000 | $0 | I - Informal Settlement |
Investigation Summary
An employee was painting the interior of a 15,000-gallon water storage tank with epoxy primer paint. An airless spray was being used for this task. An organic vapor air purifying respirator was in use and three small exhaust fans were drawing from the 12-in. pipe openings in the tank. The employee was found dead at the bottom of the section of the tank that used for initial filling and settling. There was no confined space program or procedure in place at the time of the incident and the employee was working alone without the knowledge of the supervisor(s). The medical examiners report stated that death was caused by an overexposure to organic vapors consistent with those found in the paint formulation (MiBK, Toluene, Xylene). The Atlantic City Fire Department Confined Space Rescue Team had measured approximately three of the LEL for these vapors at the time they removed the deceased from the tank. (Please refer to Accident 201770757.)
Keywords: EXHAUST SYSTEM, VAPOR, CONFINED SPACE, XYLENE, INHALATION, TOLUENE, OVEREXPOSURE, WATER TANK, RESPIRATOR
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 302710389 | Fatality | Poisoning(Systemic) | Painters, construction and maintenance |