Powered by GoogleTranslate

Inspection Detail

Inspection: 302682000 - Brian S Spilka

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 302682000
Report ID: 1054118
Date Opened: 08/24/1999

Site Address:
Brian S Spilka
Ts32s R2e Sec27
Prospect, OR 97536

Mailing Address:
5430 Sardine Creek Rd, Gold Hill, OR 97525

Union Status: NonUnion

SIC:0851

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/17/1999

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/10/2000


Related Activity
Type Activity Nr Safety Health
Accident 101612174
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 706035515 12/30/1999 01/05/2000 $0 $0 $0 -  
2. 01002 Serious 706002803 12/30/1999 01/05/2000 $0 $0 $0 -  
3. 01003 Serious 706001504 12/30/1999 01/05/2000 $0 $0 $0 -  
4. 01004 Serious 706008001 A 12/30/1999 01/05/2000 $0 $0 $0 -  
5. 01005 Serious 706035501 12/30/1999 01/05/2000 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201611357
Event: 08/23/1999
Electric Shock - Contact with Overhead Line thru Tree

A reforestation crew was completing a day's work. An employee on the crew was felling a 180-millimeter-diameter tree. He made the cut at a height of 1.9 meters above the ground without first making a face cut. He did not cut completely through the tree--a small piece (25 by 50 millimeters) remained on the back. The tree fell onto a 120-kilovolt overhead power line. The employee reached up with his chainsaw to cut the remaining portion of the tree and was electrocuted when the chainsaw touched the tree. Two coworkers sustained electrical burns when they tried to rescue the injured employee. The coworkers received medical treatment at a local hospital. (These two employees were not listed on injury lines on the original form.)

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTRIC SHOCK, LOGGING, E GI IC, BURN, TREE FELLING, CHAIN SAW, ELECTROCUTED, TREE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302682000 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close