Inspection: 302673546 - Kenney Manufacturing Company

Inspection Information - Office: Providence Area Office

 

Inspection Nr: 302673546
Report ID: 0112300
Date Opened: 09/12/2001

Site Address:
Kenney Manufacturing Company
1000 Jefferson Blvd.
Warwick, RI 02886

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2591

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/07/2002

Emphasis:

Case Closed: 02/06/2002


Related Activity
Type Activity Nr Safety Health
Accident 100090281
Referral 200097814 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $10,000 $0 $0 $0 $0 $10,000
Current Penalty $10,000 $0 $0 $0 $0 $10,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100304 F04 01/09/2002 01/09/2002 $5,000 $5,000 $0 -  
2. 01002 Serious 19100304 F05 V 01/09/2002 01/09/2002 $5,000 $5,000 $0 -  
3. 02001 Other 19100305 G02 III 01/09/2002 01/09/2002 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 200090272
Event: 09/11/2001
Electric Shock - Direct Contact with Energized Parts

Employee #1 was moving a conveyor between two operating pieces of equipment. One of them was a Shanklin Model Number T-7XL heat tunnel. The heat tunnel was not wired properly, because when its plug was wired, the grounding wire and one of the other wires were transposed. In addition, the cord of the heat tunnel was plugged into a cable that did not have a continuous ground connection. As Employee #1 moved the conveyer, he contacted one or both pieces of equipment. He was electrocuted.

Keywords: E GI V, ELECTRICAL, INADEQUATE MAINT, CORD SET, ELECTROCUTED, EQUIPMENT APPROVAL

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302673546 Fatality Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.