Inspection Detail
Inspection: 302603733 - Ups Masonry Corporation
Inspection Information - Office: Naperville Area Office
Site Address:
Ups Masonry Corporation
23 E. Hickory Street
Hinsdale, IL 60521
Mailing Address:
2101 South 50th Court, Cicero, IL 60804
Union Status: NonUnion
SIC:1741
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 10/01/1999
Emphasis: L:Fall, S:Construction Fatalities
Case Closed: 05/01/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 100820224 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 10 | 10 | ||||
| Current Violations | 10 | 10 | ||||
| Initial Penalty | $10,000 | $0 | $0 | $0 | $0 | $10,000 |
| Current Penalty | $10,000 | $0 | $0 | $0 | $0 | $10,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260020 B01 | 10/08/1999 | 02/28/2000 | $600 | $600 | $0 | - | ||
| 2. | 01002 | Serious | 19260451 B01 | 10/08/1999 | 10/14/1999 | $1,000 | $1,000 | $0 | - | ||
| 3. | 01003 | Serious | 19260451 B03 | 10/08/1999 | 10/14/1999 | $1,000 | $1,000 | $0 | - | ||
| 4. | 01004 | Serious | 19260451 B04 | 10/08/1999 | 10/14/1999 | $600 | $600 | $0 | - | ||
| 5. | 01005 | Serious | 19260451 F03 | 10/08/1999 | 10/14/1999 | $600 | $600 | $0 | - | ||
| 6. | 01006 | Serious | 19260451 C02 | 10/08/1999 | 10/14/1999 | $600 | $600 | $0 | - | ||
| 7. | 01007 | Serious | 19260451 G01 | 10/08/1999 | 10/14/1999 | $2,000 | $2,000 | $0 | - | ||
| 8. | 01008 | Serious | 19260451 F06 | 10/08/1999 | 10/14/1999 | $2,000 | $2,000 | $0 | - | ||
| 9. | 01009A | Serious | 19260454 B | 10/08/1999 | 02/28/2000 | $1,000 | $1,000 | $0 | - | ||
| 10. | 01009B | Serious | 19260454 A | 10/08/1999 | 02/28/2000 | $0 | $0 | $0 | - | ||
| 11. | 01010A | Serious | 19101200 E01 | 10/08/1999 | 02/28/2000 | $600 | $600 | $0 | - | ||
| 12. | 01010B | Serious | 19101200 G01 | 10/08/1999 | 02/28/2000 | $0 | $0 | $0 | - | ||
| 13. | 01010C | Serious | 19101200 H01 I | 10/08/1999 | 02/28/2000 | $0 | $0 | $0 | - |
Investigation Summary
An employee was erecting a scaffold. The scaffold was about 1 meter away from a 7200-volt overhead power line. The employee was electrocuted when he brought a section of the scaffold into contact with the power line.
Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E C, SCAFFOLD
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 302603733 | Fatality | Electric Shock | Construction laborers |