Powered by GoogleTranslate

Inspection Detail

Inspection: 302583513 - Gary Blick Trucking, Inc.

Inspection Information - Office: Boise Area Office

 

Inspection Nr: 302583513
Report ID: 1032500
Date Opened: 01/20/2000

Site Address:
Gary Blick Trucking, Inc.
7/10th Mile North Of Pole Line Road West&2700 East
Twin Falls, ID 83301

Mailing Address:
P.O. Box 635, Castleford, ID 83321

Union Status: NonUnion

SIC:4212

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/21/2000

Emphasis:

Case Closed: 07/10/2000


Related Activity
Type Activity Nr Safety Health
Complaint 76915677 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $1,750 $0 $0 $0 $0 $1,750
Current Penalty $1,590 $0 $0 $0 $0 $1,590
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 01/25/2000 02/02/2000 $795 $875 $0 02/16/2000 F - Formal Settlement  
2. 01002A Serious 19100303 B02 01/25/2000 02/02/2000 $795 $875 $0 02/16/2000 F - Formal Settlement  
3. 01002B Serious 19100305 E01 01/25/2000 02/02/2000 $0 $0 $0 02/16/2000 F - Formal Settlement  
4. 01002C Serious 19100305 G01 III 01/25/2000 02/02/2000 $0 $0 $0 02/16/2000 F - Formal Settlement  
5. 01002D Serious 19100334 A02 I 01/25/2000 02/02/2000 $0 $0 $0 02/16/2000 F - Formal Settlement  
6. 01002E Serious 19100334 A04 01/25/2000 02/02/2000 $0 $0 $0 02/16/2000 F - Formal Settlement  
7. 01002F Serious 19100334 C02 01/25/2000 02/02/2000 $0 $0 $0 02/16/2000 F - Formal Settlement  

Investigation Summary

Investigation Nr: 200230720
Event: 01/19/2000
ELECTRIC SHOCK - GROUND FAULT IN EXTENSION CORD SET

A 207-volt, three-phase extension cord set was lying on muddy, wet ground. At least one of the three 120-volt conductors within the plug energized the ground. An employee contacted a metal conveyor located near the plug and received an electric shock. He could not let go of the metal conveyor frame. The circuit breaker protecting the circuit with the cord set apparently opened, and the employee fell to the ground. A physician checked the injured employee, who subsequently returned to work.

Keywords: E GI V, ELECTRICAL, CORD SET, ATTACHMENT PLUG, GROUND FAULT, CONVEYOR, EQUIPMENT GROUNDING, ELECTRIC SHOCK, WATER

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302583513 Non Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.