Inspection Detail
Inspection: 302575519 - Contemporary Constructors Inc.
Inspection Information - Office: Houston North
Site Address:
Contemporary Constructors Inc.
22502 Fm 105
Cleveland, TX 77327
Mailing Address:
10925 Kinghurst, Suite 516, Houston, TX 77099
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 11/09/2000
Planning Guide: Safety-Construction
Emphasis: S:Construction, S:Construction Fatalities
Case Closed: 02/22/2001
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 361141872 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $4,000 | $0 | $0 | $0 | $0 | $4,000 |
Current Penalty | $3,000 | $0 | $0 | $0 | $0 | $3,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260550 A15 IV | 02/06/2001 | 02/16/2001 | $3,000 | $4,000 | $0 | I - Informal Settlement |
Investigation Summary
A crane company was unloading tower equipment when the boom of a crane contacted an overhead power line. An employee of another contractor, who was unloading equipment, was in contact with the rigging and was electrocuted.
Keywords:overhead power line, electrical, boom, crane boom, electrocuted, e c, crane
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 302575519 | Fatality | Electric Shock | Occupation not reported |