Powered by GoogleTranslate

Inspection Detail

Inspection: 302572771 - Ais Basic Alliance

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 302572771
Report ID: 0626600
Date Opened: 03/21/2000

Site Address:
Ais Basic Alliance
8280 Sheldon Road
Channelview, TX 77530

Mailing Address:
1422 Center Street, Deer Park, TX 77536

Union Status: NonUnion

SIC:7389

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/25/2000

Emphasis:

Case Closed: 06/20/2001


Related Activity
Type Activity Nr Safety Health
Accident 101760783
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1
Initial Penalty $10,500 $0 $0 $0 $0 $10,500
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100134 E02 II 08/01/2000 08/18/2000 $3,500 $3,500 $0 08/23/2000 F - Formal Settlement Citation has been deleted.
2. 01001B Serious 19100134 E06 I 08/01/2000 08/18/2000 $0 $0 $0 08/23/2000 F - Formal Settlement Citation has been deleted.
3. 01002A Serious 19100134 I01 IIA 08/01/2000 08/07/2000 $3,500 $3,500 $0 08/23/2000 F - Formal Settlement  
4. 01002B Serious 19100134 I04 II 08/01/2000 08/07/2000 $0 $0 $0 08/23/2000 F - Formal Settlement  
5. 01003 Serious 19100134 K01 08/01/2000 08/18/2000 $3,500 $3,500 $0 08/23/2000 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 201761053
Event: 03/21/2000
Two employees were asphyxiated and died

Two laborers/painters were abrasive blasting boiler tubes at the Equistar Chemicals Plant. The employees were working in the "B" Boiler 48001 in unit OP-II Utilities Area. They were wearing protective equipment which included a supplied air respirator attached to a 12 pack of compressed air cylinders. A second subcontractor, Greenwade Services, Inc., was their confined space attendant. Work proceeded normally until some time after lunch, 12 a.m. At approximately 3:00 a.m. the attendant tried repeatedly to get the entrants to respond to the air horn. The attendant became concerned and called management to report the failure to communicate with the entrants. An AIS Basic employee was sent into the boiler to asses the situation. He found the two employees lying on opposite ends of the scaffolding. Equistar's HSE department later tested the compressed air 12 pack and found that it contained less than 5 percent oxygen.

Keywords: OXYGEN, OXYGEN DEFICIENCY, ASPHYXIATED, VAPOR, CONFINED SPACE, ABRASIVE BLASTING, INHALATION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302572771 Fatality Asphyxia Painters, construction and maintenance
2 302572771 Fatality Asphyxia Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.