Powered by GoogleTranslate

Inspection Detail

Inspection: 302431713 - Frigidaire Home Products

Inspection Information - Office: Sc Department Of Labor, Licensing, And Regulation

 

Inspection Nr: 302431713
Report ID: 0454510
Date Opened: 01/04/2000

Site Address:
Frigidaire Home Products
Hwy. 33, Old Cameron Rd
Orangeburg, SC 29115

Mailing Address:
11770 Berea Road, Cleveland, OH 44111

Union Status: NonUnion

SIC:3524

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/15/2000

Emphasis:

Case Closed: 02/22/2000


Related Activity
Type Activity Nr Safety Health
Accident 100370873

Investigation Summary

Investigation Nr: 200370765
Event: 12/02/1999
Employee's fingers fractured in power press

Employee #1 was operating a 56-ton full revolution Minister press when it malfunctioned and fractured two fingers on his right hand. The press was equipped with two-hand trips, a guard and a light curtain, and a brake monitor.

Keywords: FRACTURE, POWER PRESS, FINGER, TWO-HAND CONTROL, POINT OF OPERATION, PRESS OPERATOR, MECH MALFUNCTION, PRESS

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302431713 Hospitalized injury Fracture Radiologic technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close