Powered by GoogleTranslate

Inspection Detail

Inspection: 302378120 - St. Joseph Hospital

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 302378120
Report ID: 0418100
Date Opened: 12/21/1999

Site Address:
St. Joseph Hospital
2260 Wrightsboro Road
Augusta, GA 30904

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:8062

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 12/21/1999

Emphasis:

Case Closed: 05/18/2000


Related Activity
Type Activity Nr Safety Health
Accident 101280659
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 5 5
Current Violations 5 5
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $18,000 $0 $0 $0 $0 $18,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100254 A03 05/08/2000 05/11/2000 $4,500 $4,500 $0 -  
2. 01001B Serious 19100254 D06 05/08/2000 05/18/2000 $0 $0 $0 -  
3. 01002 Serious 19100254 C02 V 05/08/2000 05/11/2000 $4,500 $4,500 $0 -  
4. 01003A Serious 19100254 D09 I 05/08/2000 05/11/2000 $4,500 $4,500 $0 -  
5. 01003B Serious 19100254 D09 III 05/08/2000 05/11/2000 $0 $0 $0 -  
6. 01004 Serious 19100303 G02 I 05/08/2000 05/11/2000 $2,250 $2,250 $0 -  
7. 01005A Serious 19100305 B01 05/08/2000 05/11/2000 $2,250 $2,250 $0 -  
8. 01005B Serious 19100305 B02 05/08/2000 05/11/2000 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 201280625
Event: 12/19/1999
Electric Shock - Direct Contact with Energized Conductor

A maintenance employee at a hospital was welding a dumpster to make it waterproof. The cables to the welder were in very poor condition--the insulation was split, exposing the conductors. The welding machine was located in a boiler room adjacent to the dumpster. The cable, which had been run from the boiler room to the dumpster area, was lying around the employee's feet and legs. The boiler room floor was constructed of concrete and had a metal grate over a water drain moat. The cable ran across the boiler room floor through a metal window frame. The ground lead connection was through a length of completely threaded rod. The rod had been bent and twisted so that the ends would press against the dumpster and the metal grate. The employee was found face down near the dumpster. He was dead. The hospital claimed that the cause of death could have been a heart attack, but the coroner considered it a possible electrocution. There was evidence of arcing at the window frame, the metal grate, and where the threaded rod had been touching the dumpster.

Keywords: ELEC INSULATION, E GI III, ELECTRICAL, ELECTROCUTED, WELDER, WELDING, WELDING CABLE, WELDING ELECTRODE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302378120 Fatality Electric Shock Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close