Inspection Detail
Inspection: 302376199 - C.S.S.I.
Inspection Information - Office: Atlanta East Area Office
Site Address:
C.S.S.I.
South Tower Smyrna Rd. Rockdale Coutny
Conyers, GA 30012
Mailing Address:
606 Kellam Road, Dublin, GA 31021
Union Status: NonUnion
SIC:7699
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/10/1999
Emphasis:
Case Closed: 10/23/2000
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 101280550 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $18,900 | $0 | $0 | $0 | $0 | $18,900 |
| Current Penalty | $10,000 | $0 | $0 | $0 | $0 | $10,000 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100027 D05 | 12/02/1999 | 12/21/1999 | $6,300 | $6,300 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 2. | 01002 | Serious | 19100268 G01 | 12/02/1999 | 12/21/1999 | $6,300 | $6,300 | $0 | I - Informal Settlement | Citation has been deleted. | |
| 3. | 01003 | Serious | 19100268 E | 12/02/1999 | 12/21/1999 | $3,700 | $6,300 | $0 | I - Informal Settlement | ||
| 4. | 01004A | Serious | 19100027 D05 | 12/02/1999 | 12/21/1999 | $6,300 | $0 | $0 | Q - National Office Adjustment | ||
| 5. | 01004B | Serious | 19100268 G01 | 12/02/1999 | 12/21/1999 | $0 | $0 | $0 | - |
Investigation Summary
An employee working on the Rockdale County emergency services communication tower was not equipped with a lanyard and was not using his positioning device on his safety harness. The employee positioned himself in front of a strobe light, which was mounted to the tower by metal extrusions. The strobe light was installed out from the tower, farther than what the employee could safely reach and hold onto. The employee opened the strobe light fixture cover to trouble shoot the electrical failure when he fell 600 ft to the ground and died.
Keywords: COMMUNICATION TOWER, SAFETY BELT, LANYARD, FALL, FALL PROTECTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 302376199 | Fatality | Other | Occupation not reported |
Translate