Powered by GoogleTranslate

Inspection Detail

Inspection: 302134069 - Souza Valante Hardwood Floors

Inspection Information - Office: Parsippany Area Office

 

Inspection Nr: 302134069
Report ID: 0214200
Date Opened: 07/01/1999

Site Address:
Souza Valante Hardwood Floors
1480 Rt. 46 Apr 431a
Parsippany, NJ 07054

Mailing Address:
560 2nd Ave. Apt 5, Long Branch, NJ 07740

Union Status: NonUnion

SIC:1752

NAICS: 0 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/08/1999

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 05/29/2002


Related Activity
Type Activity Nr Safety Health
Referral 200024768 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 3 1 5
Current Violations 1 3 1 5
Initial Penalty $2,000 $33,000 $0 $400 $0 $35,400
Current Penalty $2,000 $33,000 $0 $400 $0 $35,400
FTA Penalty $0 $0 $0 $4,000 $0 $4,000

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Willful 19260059 E01 10/27/1999 12/15/1999 $11,000 $11,000 $0 -  
2. 01002 Willful 19260150 A01 10/27/1999 12/15/1999 $11,000 $11,000 $0 -  
3. 01003 Willful 19260150 C01 VI 10/27/1999 12/15/1999 $11,000 $11,000 $0 -  
4. 01004 Serious 19260152 F03 10/27/1999 11/01/1999 $2,000 $2,000 $0 -  
5. 02001 Other 19030019 D01 02/04/2000 03/23/2000 $400 $400 $4,000 -  

Investigation Summary

Investigation Nr: 200021475
Event: 06/30/1999
Employee burned when chemical stripper vapors ignite

Employee #1 was stripping floors in an apartment when the circuit breaker panel was turned on and a flash fire erupted. Employee #1 sustained burns, for which he was hospitalized. There was no ventilation in the apartment.

Keywords: BURN, VENTILATION, FLAMMABLE LIQUID, FLAMMABLE VAPORS, WORK RULES, FIRE, CONSTRUCTION, CIRCUIT BREAKER, CLEANING FLUID, CHEMICAL VAPOR

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302134069 Hospitalized injury Burn/Scald(Heat) Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.