Inspection Detail
Inspection: 302103064 - Quality Controls & Equipment Inc Rig Number 5
Inspection Information - Office: Corpus Christi Area Office
Site Address:
Quality Controls & Equipment Inc Rig Number 5
5151 Highway 35 North
Rockport, TX 78382
Mailing Address:
4654 Baldwin Boulevard, Corpus Christi, TX 78408
Union Status: NonUnion
SIC:1389
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/19/1999
Emphasis: L:Oilgas
Case Closed: 08/12/2002
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 100210798 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 5 | 5 | ||||
Current Violations | 5 | 5 | ||||
Initial Penalty | $6,450 | $0 | $0 | $0 | $0 | $6,450 |
Current Penalty | $6,450 | $0 | $0 | $0 | $0 | $6,450 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5A0001 | 05/17/2000 | 05/21/2000 | $1,500 | $1,500 | $0 | - | ||
2. | 01002 | Serious | 5A0001 | 05/17/2000 | 05/21/2000 | $1,500 | $1,500 | $0 | - | ||
3. | 01003 | Serious | 5A0001 | 05/17/2000 | 05/21/2000 | $1,500 | $1,500 | $0 | - | ||
4. | 01004 | Serious | 19100027 D05 | 05/17/2000 | 05/21/2000 | $1,500 | $1,500 | $0 | - | ||
5. | 01005 | Serious | 19100151 B | 05/17/2000 | 06/04/2000 | $450 | $450 | $0 | - |
Investigation Summary
On November 17, 1999, Employee #1 and two other employees were extracting natural gases from a well. Employee #1 did not bring a drilling mud circulating tank to the jobsite and consequently had no way to circulate the contents at the bottom of the well in order to clear the well of all pockets of natural gas. He then removed the polished rod and then installed the rod blowout preventer and removed sixteen pieces of three 25 ft sections of sucker rods from the pumping well which were hung from the hanger at the rod basket in the derrick. The rod basket was located approximately 80 ft above ground level. The pipe racking board was located 57.5 ft above ground level. After these sucker rods were removed, Employee #1 detached the rod blowout preventer. He then disconnected the top flange on the "B1" Section of the wellbore sending natural gas and light weight crude oil approximately 15 ft into the air. The other employees were in the process of reconnecting the "B1" Section to the tree (i.e., wellbore), when the volatile gas and vapors ignited severely burning all three employees. The employees were hospitalized to receive treatment for burns to multiple regions of their arms.
Keywords: BURN, GAS WELL, FLAMMABLE VAPORS, GAS, DRILL RIG--NON-OIL, ARM
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 302103064 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
2 | 302103064 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
3 | 302103064 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |