Powered by GoogleTranslate

Inspection Detail

Inspection: 302050612 - Arbor Tree Surgery Inc

Inspection Information - Office: Or-E-Salem 1054100

 

Inspection Nr: 302050612
Report ID: 1054118
Date Opened: 09/28/1998

Site Address:
Arbor Tree Surgery Inc
27th & Oak St
Eugene, OR 97402

Mailing Address:
32404 Mckinley Ave, Cottage Grove, OR 97424

Union Status: NonUnion

SIC:0783

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/24/1999

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 02/23/2003


Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 6 1 7
Current Violations 6 1 7
Initial Penalty $25,500 $0 $0 $500 $0 $26,000
Current Penalty $2,600 $0 $0 $100 $0 $2,700
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100269 A02 I 03/25/1999 03/30/1999 $500 $5,000 $0 04/13/1999 F - Formal Settlement  
2. 01002 Serious 19100269 P04 I 03/25/1999 03/30/1999 $500 $5,000 $0 04/13/1999 F - Formal Settlement  
3. 01003 Serious 19100269 P04 II 03/25/1999 03/30/1999 $500 $5,000 $0 04/13/1999 F - Formal Settlement  
4. 01004 Serious 19100067 C03 03/25/1999 03/30/1999 $500 $5,000 $0 04/13/1999 F - Formal Settlement  
5. 01005 Serious 19100067 C02 V 03/25/1999 03/30/1999 $500 $5,000 $0 04/13/1999 F - Formal Settlement  
6. 01006 Serious 702022303 B 03/25/1999 03/30/1999 $100 $500 $0 04/13/1999 F - Formal Settlement  
7. 02007 Other 701076502 A 03/25/1999 04/11/1999 $100 $500 $0 04/13/1999 F - Formal Settlement  

Investigation Summary

Investigation Nr: 201610672
Event: 09/28/1998
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

A line-clearance tree trimmer was in an aerial lift trimming trees away from overhead power, cable television, and telephone lines. Apparently, as the employee started to raise the bucket, he hooked the cable television line on the controls, trapping them in a position raising the bucket. As he was trying to lift the cable from the controls, the employee continued to be elevated into the three 12-kilovolt power line conductors above him. He received an electric shock and sustained multiple burns where he contacted the three conductors. The ground worker lowered the injured employee, started first aid, and summoned emergency medical services. The injured employee was hospitalized in a burn center.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, COMMUNICATION CABLE, E PTD, ELEC UTILITY WORK, ELECTRIC SHOCK, AERIAL LIFT CONTROLS, TREE TRIMMING, AERIAL LIFT

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 302050612 Hospitalized injury Electric Shock Forestry workers, except logging
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close