Inspection Detail
Inspection: 302049903 - Hardwood Components Inc
Inspection Information - Office: Or-E-Salem 1054100
Site Address:
Hardwood Components Inc
20573 Hwy 22
Mehama, OR 97384
Mailing Address:
Po Box 39, Mehama, OR 97384
Union Status: NonUnion
SIC:2429
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/10/1998
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 04/02/1999
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $2,800 | $0 | $0 | $0 | $0 | $2,800 |
| Current Penalty | $1,200 | $0 | $0 | $0 | $0 | $1,200 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100332 B01 | 01/15/1999 | 01/21/1999 | $0 | $1,250 | $0 | 01/28/1999 | L - State Settlement | Citation has been deleted. |
| 2. | 01002 | Serious | 19100147 C06 II | 01/15/1999 | 01/21/1999 | $200 | $300 | $0 | 01/28/1999 | L - State Settlement | |
| 3. | 01003 | Serious | 19100147 D04 I | 01/15/1999 | 01/21/1999 | $1,000 | $1,250 | $0 | 01/28/1999 | L - State Settlement |
Investigation Summary
An employee was rewiring an electric switch for a planer. He disconnected the switch at the machine, assuming that that would deenergize the switch. However, the 480-volt switch remained energized, and the employee was electrocuted. (He also had severe burns his hand and arm.)
Keywords: E GI IV, ELECTRICAL, ELECTRIC SWITCH, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, ELEC CIRC PART--MISC
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 302049903 | Fatality | Electric Shock | Occupation not reported |